Open Access
Table 4
Spot Distance, Track Distance, and Dose calculated for different exemplary combinations of dose (F1 · F2) and asymmetry (F2/F1) for a particular LIOB Threshold Energy (50 nj) and Single pulse energy (Ep = 100 nJ).
| F1 · F2 | F2/F1 | F1 | F2 | Eth (nJ) | Ep (nJ) | Bubble diameter (μm) | Spot distance (μm) | Track distance (μm) | Dose (mJ/cm2) |
|---|---|---|---|---|---|---|---|---|---|
| 1.27 | 1.27 | 1.00 | 1.27 | 50 | 100 | 5.3 | 5.3 | 4.2 | 446 |
| 1.43 | 1.60 | 0.95 | 1.51 | 50 | 100 | 5.3 | 5.7 | 3.5 | 500 |
| 1.60 | 2.00 | 0.89 | 1.79 | 50 | 100 | 5.3 | 6.0 | 3.0 | 559 |
| 1.79 | 2.63 | 0.82 | 2.17 | 50 | 100 | 5.3 | 6.5 | 2.5 | 626 |
| 2.00 | 3.46 | 0.76 | 2.63 | 50 | 100 | 5.3 | 7.0 | 2.0 | 701 |