Issue |
J. Eur. Opt. Soc.-Rapid Publ.
Volume 6, 2011
|
|
---|---|---|
Article Number | 11046 | |
Number of page(s) | 8 | |
DOI | https://doi.org/10.2971/jeos.2011.11046 | |
Published online | 04 November 2011 |
Regular papers
Assessment of the scattering by sub-micron particles in inland waters
1
Institute for Environmental Sciences, Vrije Universiteit Amsterdam, De Boelelaan 1087, 1081 HV Amsterdam, The Netherlands
2
Current address: Water Insight BV, Marijkeweg 22, 6709 PG Wageningen, The Netherlands
3
CSIRO Land and Water, Clunies Ross Street, Black Mountain ACT 2601, Australia
Received:
1
June
2011
Current protocols prescribe 0.2 µm filters for absorption measurements of Coloured Dissolved Organic Matter (a(CDOM)). However, a large historical dataset of a(CDOM) was obtained over 0.7 µm filters. Since small particles may pass 0.7 µm filters, a(CDOM) was probably overestimated because of residual scattering. Furthermore, current protocols require suspended matter to be filtered over 0.7 µm. So the 0.2 µm - 0.7 µm fraction is missing from the particles and attributed to enhanced a(CDOM), potentially leading to poor optical closure. In this paper natural water samples from a eutrophic lake were analysed with both filter pore sizes and two different absorption determination methods. Besides a standard bench spectrometer with a cuvette a calibrated Point-Source integrating-Cavity Absorption Meter (PSICAM) was used to gauge the absorption measurements. After filtration over 0.7 µm we found a systematic 8% overestimation of a(CDOM) measured in the cuvette caused by residual scattering. By filtering over 0.2 µm the a(CDOM) cuvette values are 6% underestimated because also a significant fraction of absorption was removed from the sample. As a consequence we recommend testing for coloured residues on the 0.2 µm filter after prime filtration with a glass-fibre (GF/F) filter. In case the 0.2 µm filter shows colouration, the method presented in this paper is a fast and simple check to correct the CDOM measurements.
Key words: Gilvin / CDOM / filtration protocols / scattering / absorption / lakes / PSICAM
© The Author(s) 2011. All rights reserved.
Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.
Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.
Initial download of the metrics may take a while.