Gaussian beam radius (wt = ws) at different positions within the passive Q-switched Nd:YAG laser cavity for 4 cavity configurations.
| Setup | Beam radius (µm) at concave mirror ( ) |
Beam radius (µm) at input of Nd:YAG crystal ( ) |
Beam radius (µm) at output of Nr:YAG crystal ( ) |
Beam radius (µm) at input of Cr:YAG crystal ( ) |
Beam radius (µm) at output of Cr:YAG crystal ( ) |
Beam radius (µm) at plane mirror ( ) |
|
Ltotal (mm) |
|---|---|---|---|---|---|---|---|---|
| 1 | 393.507 | 356.762 | 323.768 | 299.479 | 298.713 | 290.401 | 1 | 275 |
| 2 | 453.231 | 393.273 | 352.561 | 308.199 | 307.073 | 288.298 | 1 | 345 |
| 3 | 518.145 | 428.932 | 379.942 | 314.681 | 313.095 | 276.427 | 1 | 405 |
| 4 | 617.639 | 479.745 | 418.224 | 320.422 | 318.122 | 250.594 | 1 | 465 |