Maximum extended diameter, extended diameter at 1 MHz, ablation diameter at 1 MHz and ablation depth at 1 MHz for PVC, PET and PP at 515 nm and 343 nm irradiation.
Polymer and wavelength | Max. extended diameter | Extended diameter at 1 MHz | Ablation diameter at 1 MHz | Ablation depth at 1 MHz |
---|---|---|---|---|
PVC (515 nm) | 96 μm | 76 μm | 36 μm | 40 μm |
PVC (343 nm) | 90 μm | 67 μm | 20 μm | 38 μm |
PET (515 nm) | 122 μm | 90 μm | 37 μm | 40 μm |
PET (343 nm) | 105 μm | 89 μm | 33 μm | 33 μm |
PP (515 nm) | 51 μm | 51 μm | 29 μm | 22 μm |
PP (343 nm) | 33 μm | 33 μm | 13 μm | 21 μm |